Your Reliable and Promising Partner

Tecpel Home page

Tecpel test instruments
*

200 KHz LCR Meter  w/RS-232 Interface

Model : LCR-200

bench lcr meter

Model: LCR 200

FEATURES :
Measurement Parameters : Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and θ.

Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz Basic Accuracy 0.1% ; Test Voltage: 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)

DMM Functionalities
Dual LCD Display with LED backlit
Open/Short Calibration
Remote Binning capacity
Auto range/ Range hold selection
RS-232 Interface
 
 
 
 LCR 200 Precision LCR Instrument
SPECIFICATIONS        CE  Mark Safety Approval

TEST CONDITON

Frequency

100Hz/120Hz/1KHz/10KHz/100KHz/200KHz

Level
1V rms/250mVrms/50mVrms/1Vdc(DCR only)
Measurement Parameters
 Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and θ.
Basic Accuracy
0.1%

PRIMARY PARAMETERS DISPLAY

Z
AC Impedance
DCR
DC Resistance
Ls
Serial Inductance
Lp
Parallel Inductance
Cs
Serial Capacitance
Cp
 Parallel Capacitance

SECONDARY PARAMETERS DISPLAY

θ
 Angle Impedance
ESR
Equivalent Series Resistance
D
Dissipation Factor
Q
Quality Factor

COMBINATIONS OF Display

Serial Mode
Z- θ, Cs-D, Cs-Q, Cs-ESR, Ls-D, Ls-Q, Ls-ESR
Parallel Mode
Cp-D, Cp-Q, Lp-D, Lp-Q

MEASUREMENT RANGE

Parameter
Range
z
0.000 Ohm to 500.0 Ohm
L
0.030 uH to 9999 H
C
0.003 pF to 80.00 mF
DCR
0.000 Ohm to 500.0 M Ohm
ESR
0.000 Ohm to 9999 Ohm
D
0.000 to 9999
Q
0.000 to 9999
θ
-180.0 degree to 180 degree
V
0.000mV to +/- 600.0V
ESR
0.000 Ohm to 9999 Ohm
D
0.000 to 9999
Q
0.000 to 9999
θ
-180.0 degree to 180 degree
V
0.000mV to +/- 600.0V
I
0.000mA to +/- 2.000A

DC VOLTAGE MEASUREMENT

Range
2V, 20V, 200V and 600V
Resolution
1mV, 10mV, 100mV, 1V
Accuracy
+/- (0.4% +3 digits)
input Impedance
1 M Ohm

AC CURRENT MEASUREMENT

Range
2A, 0.2A, 20mA and 2mA
Resolution
1mA, 10mA, 100mA, 1A
Accuracy
+/-(0.8% +5 digits) @ 40 Hz ~ 1 kHz
Input Impedance
1M ohm

AC CURRENT MEASUREMENT ( True RMS)

Range
2A, 0.2A, 20mA and 2mA
Resolution
1mA, 10mA, 100mA, 1A
Accuracy
+/-(0.8% +5 digits) @ 40 Hz ~ 1 kHz
Current Shunt
0.1 Ohm@ current > 20mA/ 10 Ohm@ current </= 20mA

CONTINUITY CHECK

Continuity Thresh hold
50 Ohm (Approximately)
Continuity Indicator
Tone Buzzer
Input Protection
600 Ohm (max)

DIODE TEST MEASUREMENT

Test Current
2.5mA ( Typical)
Open Circuit Voltage
5.0V DC (NOMINAL)
Input Protection
600V (max)

DIODE TEST MEASUREMENT

Power source
AC 110/ 220V +/- 10% ; 50 / 60 Hz
Operating Temp
0 to 40 deg C (Operating) ; < 85 % RH
Storage Temp
-20 deg to 70 deg C

GENEARL

Dimensions:
300 mm x 220 mm x 150 mm ( 11.8" x 8.7" x 5.9 ") (Dx W x H)
Weight
4.5 kgs
Standard Accessories
 (1). TL09C Kelvin Clips x 1 pc ( 2) Test Leads  x 1 pc     Power Cord x 1    ;  Instruction Manaul x 1
Optional Accessories
  (3) TL09A SMD test Probe ( 4) TL 09B Component Fixture lcr meter component fixture

Click below  for more information.


TECPEL CO., LTD.

E-MAIL : sales@tecpel.com ; oka@oka.com.tw
Tel : 886 (2)2737-5866 FAX : (02)2737-3343
Web-site: http://www.tecpel.com ; http://www.oka.com.tw

View Site in Mobile | Classic