Your Reliable and Promising Partner
200 KHz
LCR Meter w/RS-232
Interface
Model
:
LCR-200

Model: LCR 200
Measurement Parameters :
Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and θ.
Test conditions : 100MHz
, 120Hz , 1KHz , 10KHz , 100KHz , 200KHz Basic Accuracy 0.1% ; Test Voltage: 1Vrms , 250mVrms , 50mVrms ,
1Vdc(DCR only)
Dual LCD Display with LED
backlit
Auto range/ Range hold
selection
LCR 200 Precision
LCR Instrument
SPECIFICATIONS
CE Mark Safety Approval
Frequency
100Hz/120Hz/1KHz/10KHz/100KHz/200KHz
Level
1V
rms/250mVrms/50mVrms/1Vdc(DCR only)
Measurement
Parameters
Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and
θ.
PRIMARY PARAMETERS DISPLAY
Z
AC Impedance
SECONDARY PARAMETERS DISPLAY
θ
Angle Impedance
ESR
Equivalent Series
Resistance
Serial Mode
Z-
θ, Cs-D, Cs-Q, Cs-ESR, Ls-D, Ls-Q,
Ls-ESR
Parallel
Mode
Cp-D, Cp-Q, Lp-D,
Lp-Q
DCR
0.000 Ohm to 500.0 M
Ohm
ESR
0.000 Ohm to 9999
Ohm
θ
-180.0 degree to 180
degree
ESR
0.000 Ohm to 9999
Ohm
θ
-180.0 degree to 180
degree
Range
2V, 20V, 200V and
600V
Resolution
1mV, 10mV, 100mV,
1V
Accuracy
+/- (0.4% +3
digits)
Range
2A, 0.2A, 20mA and
2mA
Resolution
1mA, 10mA, 100mA,
1A
Accuracy
+/-(0.8% +5 digits) @ 40
Hz ~ 1 kHz
AC
CURRENT MEASUREMENT ( True RMS)
Range
2A, 0.2A, 20mA and
2mA
Resolution
1mA, 10mA, 100mA,
1A
Accuracy
+/-(0.8% +5 digits) @ 40
Hz ~ 1 kHz
Current
Shunt
0.1 Ohm@ current >
20mA/ 10 Ohm@ current </= 20mA
Continuity Thresh
hold
50 Ohm
(Approximately)
Continuity
Indicator
Tone Buzzer
Input
Protection
600 Ohm (max)
Test Current
2.5mA (
Typical)
Open Circuit
Voltage
5.0V DC
(NOMINAL)
Input
Protection
600V (max)
Power source
AC 110/ 220V +/- 10% ; 50
/ 60 Hz
Operating Temp
0 to 40 deg
C (Operating) ; < 85 % RH
Storage Temp
-20 deg to 70 deg
C
Dimensions:
300 mm x 220 mm x 150 mm (
11.8" x 8.7" x 5.9 ") (Dx W x H)
Standard
Accessories
(1). TL09C Kelvin
Clips x 1 pc ( 2) Test Leads x 1 pc Power
Cord x 1 ; Instruction Manaul x 1
Optional
Accessories
(3) TL09A SMD test
Probe ( 4) TL 09B Component Fixture

Click below for more information.