Four inputs. One temperature record.

TECPEL DTM-319 4-Channel Thermocouple Data Logger

Measure, compare and record four Type K temperatures with one portable instrument.

Bring multiple test points into a single measurement workflow. The DTM-319 combines simultaneous temperature monitoring, internal data storage and PC connectivity for practical laboratory and field testing.

Need help selecting probes? Tell us your temperature range and application.

TECPEL DTM-319 handheld temperature logger with four Type K inputs and thermocouple probe
DTM-319 · Four Type K thermocouple inputs
4 channels Simultaneous temperature recording
-200 to 1370°C Instrument measurement range
16,000 Stored records per channel
0.1°C / °F Resolution in the applicable range
Built for multi-point measurements

Follow the temperature at every test point

Use four thermocouple inputs to compare temperature conditions across a test setup. Record changes over time and review your measurements with the appropriate PC connection and software.

01 / MEASURE

Four temperatures together

Read four Type K probes simultaneously. Keep measurement points connected while comparing conditions across your equipment or process.

02 / RECORD

Internal data logging

Store up to 16,000 records per channel. Configure the recording interval to suit your observation period.

03 / REVIEW

Practical everyday controls

Use HOLD and MAX / MIN functions to examine readings. Select Celsius or Fahrenheit for your reporting needs.

Application ideas

One logger, multiple temperature perspectives

Select the right Type K probes for the temperature range, surface or medium you need to measure.

HVAC & maintenance

Compare temperature points around air-handling equipment or thermal systems using suitable air and contact probes.

Laboratory & development

Observe heating and cooling at multiple locations during experiments, prototype evaluation and repeatable bench tests.

Production & process checks

Record temperature changes during equipment checks and process trials. Match probe ratings to the actual test conditions.

Technical data

DTM-319 specifications

Specifications below refer to the Type K DTM-319. Confirm your required cable, software and probe configuration when ordering.

Measurement and instrument specifications
Parameter Specification
Input channels 4 channels; Type K thermocouples
Temperature range -200 to 1370°C (-328 to 2498°F)
Display resolution 0.1°C / 0.1°F; 1°C from 200 to 1370°C
Sampling rate One measurement cycle every 3 seconds
Memory 16,000 records per channel
Recording interval User configurable
Display and functions Four-digit LCD for each point; °C / °F selection; HOLD; MAX / MIN
PC connection RS-232 interface; USB connection available with the appropriate cable / adapter
Power supply One 9V battery; optional 9V DC adapter
Dimensions 184 × 64 × 30 mm
Weight Approximately 210 g
Additional features Automatic power-off; low-battery indication; standard tripod mount
Published accuracy in Celsius
Temperature range Accuracy
-200 to 200°C ±(0.2% of reading + 1°C)
200 to 400°C ±(0.5% of reading + 1°C)
400 to 1370°C ±(0.2% of reading + 1°C)

The instrument range does not define the temperature rating of an attached probe. Select a thermocouple with the correct range and construction for the application. Probe error and measurement conditions also affect the complete measurement result.

Configure your measurement kit

Probes, connection and carrying case

Build a practical four-point measurement setup with Type K probes and the PC connection suited to your computer.

  • Four TPK-01 Type K bead probes
  • Protective carrying case and operating instructions
  • PC software and interface cable configuration
  • Optional 9V DC adapter
  • Optional application-specific Type K probes

Package contents and cable bundles may vary. The product photograph shows a USB cable kit; the published instrument specification identifies an RS-232 interface. Confirm the supplied adapter, driver and Windows compatibility with TECPEL.

Explore TPK-01 thermocouple probes
DTM-319 accessory kit showing protective case, four Type K bead probes, cable, battery and manuals
Illustrated accessory kit. Confirm the current supply configuration.
Selection & operation

Frequently asked questions

Can the DTM-319 record four temperatures at once?

Yes. The DTM-319 accepts four Type K thermocouples and can display and record four measurement points simultaneously.

Does the DTM-319 support Type J, E or T probes?

This DTM-319 page covers the Type K model. If you need other thermocouple types, ask TECPEL to recommend a suitable model, such as the DTM-319A.

Does the included probe cover the full -200 to 1370°C range?

The stated range is the instrument range. Each probe has its own temperature limit. Choose a probe rated for your measurement temperature, medium and contact method.

How does the DTM-319 connect to a computer?

The instrument uses an RS-232 interface. USB connection requires the appropriate cable or adapter and driver. Confirm the supplied cable and software compatibility with TECPEL when ordering.

How much temperature data can it store?

The published storage capacity is 16,000 records per channel. Select a recording interval suitable for the length of your test and the speed of the temperature changes.

Plan your four-channel temperature test

Send TECPEL your required quantity, temperature range, probe type and PC connection needs. We can help you select a suitable DTM-319 configuration.

Email your inquiry

Product reference: TECPEL DTM-319 technical listing · TECPEL product catalog