Propel Quality Measurement

Tecpel Test and Meausrement Home Page

Tecpel test and Measurements product guide
*

1000Amp AC/DC Clamp Adapter

transmitter

Model: CA-1000D

Features :

1000Amp AC/DC Clamp Adapter

1000Amp AC/DC Clamp Adapter  Transmitter

Model:CA-1000D

Features :

☆ 1000A AC or DC Current Clamp

☆ Measure current without disconnecting circuit under test
☆ Measure to 1000A DC or AC
☆ Outputs 1mV per Amp, operates on 2V range of any DMM

SPECIFICATIONS        CE  Mark Safety Approval


Specifications :

  • DC Current Range:

    0-1000A ± (1.5~3.5%+3A)

    AC Current Range:

    0-1000A ± (1.5~3.5%+3A)

    Output

    0-1V rms or DC with>=1M Ω input impedance

    Transfer Rate:

    1mV/1A

    Overload Protection

    1200A for 60 seconds maximum.

    General

    Jaws Opening Capability:

    57mm Conductor, 70 x 18 mm bus bars

    Power Requirement:

    One 9V battery

    Dimensions:

    9.6 " x3.9 "x1.6" (244x100x40mm)

  • CA-06 Adapter (Option)
    • BNC- Female 4mm Banana post adapter for receiving Signal output from CA-60 and able to be monitored by oscilloscope.

    Current transmitter adapter BNC- 4mm Banana post

    Use LF-180 and TL-19 together to connect CA-1000D with any oscilloscope

    to monitor low frequency signal.

    LF-180 BNC Probe- 4mm Male Banaba connector TL-19 Female 4mm to Female 4mm socket for connecting 4mm Banana male Jack
    LF-180 BNC Probe to Male 4mm Banana connector Female 4mm hole to Female 4 mm hole


TECPEL CO., LTD.

E-MAIL : sales@tecpel.com ; oka@oka.com.tw
Tel : 886 (2)2737-5866  FAX : (02)2737-3343
Web-site: http://www.tecpel.com ; http://www.oka.com.tw