Infraed thermometers: Laser, No contact, Digital

Infraed thermometers:  Laser, No contact, Digital


DIT-516 laser type (–32°C~ +650 °C)
DIT-517 laser type (–32°C~ +1050°C)
DIT-518 laser type (–32 °C~ +1550°C)

Key Features:

  • Temperature measurement:
  • DIT-516 (–32°C~ +650 °C), DIT-517 (–32 °C~ +1050 °C), DIT-518 (–32 °C~ +1550 °C)
  • High accuracy: +/- 1.8 % ; or +/- 1.8 °C
  • Emissivity 0.10 to 1.0 digitally adjustable, adjustable rate 0.01
  • Single point laser light: accurate aiming of objects
  • Temperature analysis: reading 0.1 °C
  • Distance and measurement ratio DIT-516 (20:1) ; DIT-517 ( 30: 1) ; DIT-518 : (50: 1)
  • Maximum, Minimum, average and high and low temperature difference,
  • present value temperature display and final measured temperature display
  • Auto power off function, low battery display function
  • Backlight display, laser switch function
  • External tripod
  • External USB function, remember 99 pens (limited to model DIT-518)
  • External thermocouple K-type measuring line or measuring rod (limited to model DIT-518)
  • High and low alarm function (limited to model DIT-518) 

dIGITAL INFRARED THERMOMETER

BASIC SPECIFICATION



Model Number

DIT-516

DIT-517
DIT-518
Outlook
Infrared thermometer laser gun type non contact Tecpel DIT-516   (–32℃~ +650 ℃ )
Infrared thermometer gun type non contact  DIT-517  –32℃~ +1050℃ )
infrared thermometer laser gun type non contact High  temperature meter  Tecpel DIT-518 –32 ℃~ +1550℃ )
Temperature Range

–32 ~ +650 ℃ 

–32 ~ +1050 ℃ 

–32 ~ +1550 ℃ 

Distance & Spot ( D:S)

20:1

30:1
50:1
Emmisviity

0.1 to 1.0 adjustable

Laser point

 Single type Class 2 (II) , Output is 1mV, Wave length 630 ~ 670 nm

Final Temp. Dislay

V

Temperature Display

Instant, Max, Minimum, Max/Min Difference, Average

LCD Backlight
V
Hold Display
8  Sec.
Temperature Resolutin
            0.1
Accuracy
Reading  +/- 1.8% or +/- 1.8         at 23 ~ 25
Repetitive
     +/-  0.5 % or +/- 0.5
Response time
250m sec.( 95% reading)
 Spectral response
8 to14 ( um)
Operation temperature
           0 to 50 
Relative Humidity
10 to 75 % RH
Weight/Dimensions
322 g / 17.69cm(H) x 16.36cm(L) x 5.18cm (W) (Limited to infrared thermometer itself)
Power source
6F22 9V Battery, Alkaline Battery can use for 30 hours., Normal 10Hrs.
6F22 9V Battery, Alkaline Battery can use for 30 hours., Normal 10Hrs. 
 6F22 9V Battery, Alkaline Battery can use for 30 hours., Normal 10Hrs. or USB
 Data Hold
8 Sec.
8 sec
8Sec.
USB interface
Nile
Nile
yes
Data logging capacity
Nile
Nile
99 points
Packaging
紅外線溫度計 Tecpel DIT-516 單點雷射型 (–32℃~ +650 ℃ )
紅外線溫度計 DIT-517單點雷射型(–32℃~ +1050℃ )
紅外線溫度計 Tecpel DIT-518 單點雷射型 (–32 ℃~ +1550℃ )

Infrared thermometer Application Fields:

For Food factory, cement factory, electronic machinery factory, textile factory, steel factory, air conditioning refrigeration, printing factory, biochemical pharmaceutical factory, etc.

Application notes:

1. The infrared thermometer can obtain accurate temperature via infrared transmission without touching the object, as long as the infrared ray is aligned. The measured object can obtain the precise temperature of the measured object in less than 1 second.

2. How to choose an infrared thermometer:

a. Select the desired temperature range

b.Confirm the measured object:

B-1. Material: Infrared thermometer is not suitable for measuring metal materials that reflect light. To measure this material, apply black paint as temperature transforming material or Adhesive tape with a reflectance of 0.95

B-2. Size: Usually the object to be measured must have a minimum diameter of 20 mm or more.

(If you have special requirements, please contact us; if you need to measure small objects 2.5mm, you need to use OPTEX PT-3S. Please refer to the website.

http://www.oka.com.tw/tw/p/Product-2002102211594_32.html 

B-3. ​​Measuring distance: determined by D: S value: The greater the D:S ratio, the farther the measurable distance is. For example, the above figure shows

c. Emmisivity (0.1 ~ 1): The Emmisiviity of each object is not the same, the general object measurement setting is 0.95 for normal material.

e. Application of emmisivity meter

High temperature professional infrared thermometer software application

Software application (limited to DIT-518)

1. Recordable EXCEL (*.xls), text file (*.txt) and database file (*.dB)

2. Sampling time 1 ~ 999 times / sec 3. The number of X-axis recordings can be set more than 10,000 (recorded by computer)

High temeprature professional infrared thermometer software operation.


www.facebook.com/testinstrument http://www.linkedin.com/in/tecpel https://twitter.com/tecpelco Tecpel- Test Instrument
at www.youtube.com D&B TECPEL-TEST INSTRUMENTS

TECPEL CO., LTD.

http://www.tecpel.com.tw/ http://www.oka.com.tw/

Email: sales@tecpel.com.tw; oka@oka.com.tw

Tel: 886 2 2218 3111 Fax: 886 2 2218 3222                                                           -

  • TECPEL CO., LTD. (C)1990~ 2018 Tecpel Co., Ltd. All Rights Reserved.
View Site in Mobile | Classic
Share by: