Propel Quality Measurement

Tecpel Test and measurement Home page

Tecpel Test Measurement Product Guide
*

New product Clamp meter ac/dc

AC/DC Current clamp meter ( DCM-042)

This mode is discontinued.

TECPEL DCM-042 a high high resolution AC/DC clamp meter. With the resolution of 0.l. This current clamp meter is a great tool for PWM trouble shootingand in noisy environment measurment. Inrush current(100mS) mode is very helpful for measuring start current to check motors, lighting equipment and etc. , th

Tis current clamp transmitter is a great meter for circuit measurement or for car applications.eatures :

Clamp meter DCM-042

Features of Clamp meter DCM-042

600A DC/AC True RMS Industrial Clamp Meter

  • Maximum reading of 9999
  • ACA/DCA measurement up to 600.0A
  • Inrush current (100mS) mode, for measuring start current for motors, lighting, etc.
  • Good for PWM trouble shooting and in Noisy environment measurement
  • Improved low current measurement accuracy
  • Temperature Compensation Current sensor
  • HOLD/PEAK HOLD, MAX/MIN, A-Hz and V-Hz function
  • Auto shut-off maximizes battery life
  • Large, backlit display easy to see
  • Dimensions of conductor: O35mm
  • EN61010-1 Approval. Over-Voltage Category CAT III 1000V
SPECIFICATIONS        CE  Mark Safety Approval
  • AC/DC Current Clamp meter ( DCM-042)

    Specifications:

    AC Current (accuracy: at the center of CT)

    Range: 0 to 600.0A

    Accuracy: ±(2.0%rdg+5dgts) on 20Hz to 100Hz

    ±(6.0%rdg+5dgts) on 100Hz to 400Hz

    Resolution: 0.1A

    AC Voltage

    Range: 0 to 600.0V

    Resolution: 0.1V

    Accuracy: ±(1.0%rdg+5dgts) on 20 to 100Hz

    ±(6.0%rdg+5dgts) on 100 to 400Hz

    Input impedance: 1M?

    DC Current (accuracy: at the center of CT)

    Range: 0 to 600.0A

    Accuracy: ±(2.0%rdg+5dgts)

    Resolution: 0.1A

    DC Voltage

    Range: 0 to 600.0V

    Resolution: 0.1V

    Accuracy: ±(1.0%rdg+5dgts)

    Input impedance: 1M?

    Resistance (Autorange)

    Range: 0 to 999.9?, 1000 to 9999?

    Accuracy: ±(1.5%rdg+5dgts)

    Resolution: 0.1?/1?

    Frequency

    Range: 20 to 400.0Hz

    Resolution: 0.1Hz

    Sensitivity: 5Vrms TTL signal,

    ?5A @20 to 100Hz, ?10A @100 to 400Hz

    Accuracy: ±(0.5%rdg + 5dgts)

    Diode Test

    Accuracy: ±(3.0%rdg+3dgts)

    Resolution: 0.001V

    Test current: 0.2mA

    Test Voltage: <3.0V

    Continuity

    Audible indication: less than 30?

    Capacitance

    Range: 0 to 999.9µF

    Resolution: 0.1µF

    Accuracy: ±(5.0%rdg + 10dgts)

    Temperature (K-Type Thermocouple)

    Range: -40°C to 1200°C, -40°F to 2200°F

    Accuracy: ±(0.5%rdg+1°C)

    ±(0.5%rdg+2°F), (not including thermocouple error)

    Resolution: 0.1°C on -40°C to 999.9°C

    1°C on 1000°C to 1200°C

    0.1°F on -40°F to 999.9°F

    1°F on 1000°F to 2200°F




Go to see Clamp Meter s


TECPEL CO., LTD.

E-MAIL : sales@tecpel.com ; tecpelco@gmail.com
Tel : (02)2737-5866 FAX : (02)2737-3343
Web-site: http://www.tecpel.com ; http://www.oka.com.tw

Tecpel product guide Tecpel home page Tecpel product guides

View Site in Mobile | Classic
Share by: