TECPEL - Propel Quality Measurement.

TECPEL-Test and Measurement

Tecpel Product Guide
*

 3MHz  Function Generator + 60MHz Freq. Counter

Model : FG-32

FEATURES:

6 function, 6 ranges
 Frequency Range 0.5Hz~3MHz
Linear / Log sweep fucntion.
 Frequency  Counter  0.2 ~ 60MHz
 Frequency Counter Max. Resoltuion 0.001Hz?C

Leaflet DM-1 Data Sheet DM-2

FG 32 (6  waveforms , 6 ranges ,  Freq. Counter)  :  specification   CE

 Main Output

?@Frequency Range

0.5Hz ~ 3MHz in 6 ranges , 5 digits LED display, High resolution 0.001Hz  ?Ause rotary switch to select ranges
?@Waveform
6 Waveforms ( Sins, Square, Triangle, Ramp, + Pulse, - Pulse), Use rotary switch to select waveform
?@Stability
0.1% after 15 minutes;?@?@0.2% after 24 hours
  DC OFFSET
   +/- 10 V with pull Adjust.  switch  ;  + - 10V( No load)?A + - 5V(50?[ Load)
 Ramp
   Frequency Range
0.5Hz ~ 2.5MHz?A Use 5 digits LED display
  Max. Resolution
0.001Hz
?@Symmetry
50%(Rise waveform)  to 50%( Fall waveform) Distortion??1%(1Hz ~ 100KHz)
?@Distortion
??1%(1Hz ~ 100KHz)
 Triangle
?@Frequency Range
0.5Hz ~ 3MHz?A   Use 5 digits  LED display
?@Max. Resolution
0.001Hz
    Symmetry
50%(Rise waveform)  to 50%( Fall waveform) Distortion??1%(1Hz ~ 100KHz)
?@Distortion
??1%(1Hz ~ 100KHz)
 Sine Ware
?@Frequency Range
0.5Hz ~ 3MHz?AUse 5 digits  LED display
?@Max. Resolution
0.001Hz
?@ Symmetry
50%(Rise waveform)  to 50%( Fall waveform) Distortion??1%(1Hz ~ 100KHz)
?@Distortion
??1%  to100KHz
?@Harmonic Ratio
??30dB  to3MHz
?@ Freq.  Response
??0.1dB  to 100MHz?@  ??1dB  to 3MHz
 Square
?@Frequency Range
 0.5Hz ~ 3MHz?AUse 5 digits  LED display
?@Max. Resolution
0.001Hz
?@ Symmetry
50%(Positive half circle) to 50%( Negative half cycle) distortion ??1%  to 100KHz
?@Rise Time
??60nS
  + Pulse
?@ Freq. Range
0.5Hz ~ 3MHz?AUse 5 digits  LED display
?@Max. Resolution
0.001Hz
?@+ Pulse width
0.4sec ~ 100nS(Continously variable)
?@Symmetry
50%(Positive half circle) to 50%( Negative half cycle) distortion ??1%  to 100KHz
?@Rise Time
??60nS
  - Pulse
?@Freq. Range
 0.5Hz ~ 3MHz?AUse 5 digits  LED display
?@Max Resolution
0.001Hz
?@- pulse width
0.4sec~100nS
?@Symmetry
85%(+ time base) to 15%(- Pulse) distortion ??5% to 100KHz
?@Fall time
??60nS
  Main Output
?@Output Impedance
50?[?A Distortion ??2%
?@Max. Output
20Vp-p( No load)?A0.05Vp-p(50?[ Load)?@?@Distortion?G + - 0.5V
?@Min. Output
0.1Vp-p( No load)?A0.05Vp-p(50?[ load)
?@Attenuator
-20dB  Attenuator ; Attenuation ??2%
 SYNC OUTPUT
?@Output Impedance
50?[?ADistortion ??2%
?@Output Level
TTL Level ??3Vp-p Fix Amplitude
?@Rise Time
??40nS
VCF  Input
?@Input Level
0~10V Input
?@Max. Freq. Variable Rate
1 : 1 ~ 1 : 1000
    Input Frequency
DC ~ 1KHz
  Sweep Sync Output
?@Output Impedance
1K?[?ADistortion ??2%
?@Output Waveform
 Linearity or LOG sweep  or LOG sweep slope
?@Output Amplitude
10Vp-p(load)?A5Vp-p(51K?[  Load)
?@Output Frequency
Continuously variable   , 0.2Hz ~ 100Hz
Sweep
?@Sweep Mode
LINEAR/ LOG  sweep,  Use switch selector
?@Sweep Rate
5sec ~ 10mS?AContinuously variable
    Sweep Width
1 : 1 ~ 1 : 100( To cooperate with Freq. Knob)
  Frequency Counter
?@Display
5  digits 0.36 '   Red  LED display
?@Max. Resolution
0.001Hz
?@Unit
Hz/KMz
?@ TIME BASE
20MHz
?@ Temp. Characteristic
??10PPM
?@Distortion
??0.002% ?? ?@??
?@Power source
+5V / 160mA
  Internal Counter
?@ Range
 Auto Range (0.001Hz/0.01Hz/0.001KHz/0.01KHz)?@
 Total 4 ranges , Resolution ?ACPU select one to display
?@Counter Range
0.500Hz ~ 3000.0KHz?AAuto select decimal point and display unit
?@Gate Time
Variable  0.25sec ~ 2sec  Auto set
?@ Minimum Display
 4 digits
   External Counter
   Max. Input Voltage
??250Vrms
?@Input Impedance
1M  ,  Distortion ??2%
?@Input Frequency Range
0.2Hz ~ 60MHz
?@ Attenuation switch
x20(-26nB) 
   (COUPLING)
AC(HF)-- Measure  frequency over 100KHz through capacitor coupling
DC(LF)100KHz FILTER-- Measure frequency under 100KHz direct coupling
    (GATE TIME)
 Variable 0.25sec ~ 10sec auto set by frequency
    Range
 Auto range(0.001Hz/0.01Hz/0.001KHz/0.1KHz/1KHz)  5 kinds of resolution  selected by CPU.
?@Minimum display
 4 digits
?@Input sensitivity
??30mVrms(1MHz)

Calculation  Time table for Frequency Display value/ Gate time

Standard Value GATE TIME INT EXT.HF EXT.LF
0.2Hz
10S ?? ?? 0.200Hz
0.5Hz
2S 0.500Hz ?? 0.500Hz
1Hz
1S 1.000Hz ?? 1.000Hz
10Hz
0.25S 10.000Hz ?? 10.000Hz
100Hz
0.25S 100.00Hz ?? 100.00Hz
1KHz
0.25S 1.000KHz ?? 1.000KHz
10KHz
0.25S 10.000KHz ?? 10.000KHz
100KHz
0.25S 100.0KHz 100.00KHz 100.0KHz
1MHz
0.25S 1000.0KHz 1000KHz ??
10MHz
0.25S ?? 10000KHz ??
60MHz
0.25S ?? 60000KHz ??
 General Specifications:
?@Operating Temp.
 Temperature: 0 ~ 40 C  ;   Humidity 0 ~ 90% RH
?@Power Source
AC 115V(+-10%) 50/60Hz , FUSE 600mA?C
AC 230V?@(+-10%) 50/60Hz , FUSE 300mA
Consumption
Max 25VA(Watt)
?@Heat Ventilation
 Use fan  DC 12V/100mA
?@Safety Approval
CE,GS,UL,CUL  approval
?@Dimenstions
275mm(Width) x 90mm( Height) x 300mm(Depth)
    Weight
2.5Kg( Net)
?@Accessories
 Operation Manual, Test leads, Power cord.

?@

?@


TECPEL CO., LTD.

E-MAIL : sales@tecpel.com ; oka@oka.com.tw
Tel : 886 (2)2737-5866 FAX : (02)2737-3343
Web-site: http://www.tecpel.com ; http://www.oka.com.tw

View Site in Mobile | Classic
Share by: