Propel Quality Measurement.
![]() |
* |
Oscilloscope GDS-1062A | Oscilloscope GDS-1102A | Oscilloscope GDS-1152A |
---|---|---|
![]() |
![]() |
![]() |
GDS-1062A
GDS-1102A
GDS-1152A
VERTICAL
Channels
2
2
2
Bandwidth
DC~60MHz(-3dB)
DC~100MHz(-3dB)
DC~150MHz(-3dB)
Rise Time
<5.8ns Approx.
<3.5ns Approx.
<2.3ns Approx.
Sensitivity
2mV/div ~ 10V/div (1-2-5 increments)
Accuracy
±(3% x |Readout| + 0.1 div + 1mV)
Input Coupling
AC, DC & Ground
Input Impedance
1MΩ±2%, ~15pF
Polarity
Normal & Invert
Maximum Input
300V (DC+AC peak), CATII
Waveform Signal Process
+ , - , x, FFT, FFTrms
OffsetRange
2mV/div ~ 50mV/div: ±0.4V
100mV/div ~ 500mV/div: ±4V1V/div ~ 5V/div: ±40V
10V/div: ±300V
Bandwidth Limit
20MHz (-3dB)
TRIGGER
Sources
CH1 , CH2 , Line , EXT
Modes
Auto, Normal, Single, TV, Edge, Pulse Width
Coupling
AC , DC , LF rej. , HF rej. , Noise rej.
Sensitivity
DC ~ 25MHz: Approx. 0.5div or 5mV;25MHz ~ 150MHz: Approx. 1.5div or 15mV
EXT TRIGGER
Range
±15V
Sensitivity
DC ~ 25MHz : ~ 50mV ; 25M ~ 150MHz : ~100mV
Input Impedance
1MΩ±2% , ~ 15pF
Maximum Input
300V (DC AC peak) , CATII
HORIZONTAL
Range
1ns/div ~ 50s/div (1-2.5-5 increments); ROLL : 250ms/div ~ 50s/div
Modes
Main, Window, Window Zoom, Roll, X-Y
Accuracy
±0.01%
Pre-Trigger
10 div maximum
Post-Trigger
1000 div
X-Y MODE
X-Axis Input
Channel 1
Y-Axis Input
Channel 2
Phase Shift
±3°at 100kHz
SIGNAL ACQUISITION
Real-Time Sample Rate
1GSa/s maximum
Equivalent Sample Rate
25GSa/s maximum
Vertical Resolution
8 Bits
2 Mega Points maximum
Acquisition Mode
Normal, Peak Detect, Average
Peak Detection
10ns (500ns/div ~ 10s/div)
Average
2 , 4 , 8 , 16 , 32 , 64 , 128 , 256
CURSORS AND MEASUREMENT
Voltage Measurement
Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot
Time Measurement
Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle
Cursors Measurement
Voltage difference between cursors (V)Time difference between cursors (T)
Auto Counter
Resolution : 6 digits
Accuracy: 2%
Signal Source: All available trigger source except the Video trigger mode
ADJUSTABLE PROBE COMPENSATION SIGNAL
FrequencyRange
1kHz ~ 100kHz, 1kHz/STEP
DutyCycleRange
5% ~ 95%, 5%/STEP
CONTROL PANEL FUNCTION
Autoset
Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically
Save Setup
Up to 15 sets of measurement conditions
Save Waveform
15 sets of waveform
DISPLAY
TFT LCD Type
5.6 inch
Display Resolution
234(Vertically) x 320(Horizontally) Dots
Display Graticule
8 x 10 divisions
Display Brightness
Adjustable
INTERFACE
USB Slave Connector
USB1.1 & 2.0 full speed compatible(printers and flash disk not supported)
SD Card Slot
Image (BMP), waveform data (CSV), and setup (SET)
POWER SOURCE
LineVoltageRange
AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection
MISCELLANEOUS
Multi-Language Menu
Available
Onscreen Help
Available
DIMENSIONS & WEIGHT
310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg
E-MAIL
:
sales@tecpel.com
; oka@oka.com.tw
Tel : 886 (2)2737-5866 FAX : (02)2737-3343
Web-site: http://www.tecpel.com
; http://www.oka.com.tw